| GG Series Wire Cable Isolator Installation Guide |
|
| Installation Method |
Load-Displacement / Remark |
1 base mounting  |

common installation for device with shorter height than its width
. |
2 base mounting  |

common installation with additional isolator for stabilizing (when height/width>1). |
3 45°mounting  |

common installation for machine with rotation;
similar performance on both vertical and horizontal direction;
good at both vibration and shock isolation. |
4 hanging mounting  |

common hanging installation. |
5 hanging mounting  |

lower system peak response frequency can be achieved;
take note of mechanical symmetry of the system. |
|
| Installation Method |
Load-Displacement / Remark |
6 hanging mounting |

lower system peak response frequency can be achieved;
take note of mechanical symmetry of the system.
|
7 hanging mounting |

seldom used hanging installation. |
8 hanging mounting |

common hanging installation.
|
9 top hanging mounting |

better stability;
lower loading capacity;
not recommended as only installation method.
|
10 top hanging mounting |
45° top hanging mounting better stability;
better loading capacity compared to above;
not recommended as only installation method.
|
|
|
|
|
|
|
|
|
|
|
|
|